i16 / iS16
Series
from $180
i8/iS8
- 1/8 DIN Meter
i8C/iS8C
- 1/8 DIN Ultra Compact Case
i8DV/iS8DV
- 1/8 DIN Dual Display Vertical
i8DH/iS8DH
- 1/8 DIN Dual Display Horizontal
i16/iS16
- 1/16 DIN Single & Dual Display
i32/iS32
- 1/32 DIN Meter
RD4/RD6
- 1/8 DIN Remote Display/Programmer
iLD
- Big Display
|
1/16 DIN
Single Display
|

1/16 DIN
Dual Display
|
| iSeries |
Selection Guide PDF |
| |
|
|

For Temp.Units
|
|
The
NEWPORT® i16 is the popular
1/16 DIN size (48mm square) meter or controller. The meter
(model i1600) displays the process value and has
no control outputs. The controller is available with a single
(i16) or dual display (i16D) that displays
a set point along with the process value. The i16
is the first 1/16 DIN controller with a display that can
be programmed to change color at any set point or alarm
point. The i16 is the first 1/16 DIN controller with the option of both
RS-232 and RS-485 in one instrument with both MODBUS serial
protocol and the straightforward NEWPORT®
ASCII protocol. NEWPORT®
provides free configuration and data acquisition software for the iSeries on CD-ROM
and for download off the Web.
The i16
enclosure has a NEMA 4 (IP65) rated front bezel. The electronics
are removable from the front panel.
Access
Vital Information Anytime,
Anywhere, on the World Wide Web

|
1/16
DIN Controller With Embedded Web Server,
Dual Control Outputs, Dual Display

|
The iSeries
displays feature
unique 9-segment LED characters which greatly improves
alphanumeric representations. The 7-segment LED characters
found on most instruments are adequate for presenting
numbers, but not letters. Words are easier to read with
the unique 9-segment LED characters on the iSeries,
which makes operating and programming simpler and easier.
Programmable
Color Display
The
NEWPORT®
iSeries are the first
complete series of 1/8, 1/16 and 1/32 DIN process control
instruments with totally programmable color displays. The
display can be programmed to change color at any set point
or alarm point.
|
|
iSeries
Change Color at any Setpoint
|
For example, the instrument can be programmed to display
the process value in GREEN
during warm-up, switching to AMBER
to signal the normal operating range, and in RED
to signal an alarm condition. The changes in color are quickly
seen from a distance, and machine operators can intuitively
react to changing conditions. The colors can be programmed
to change back when the value drops back below the alarm
point or to "latch" on until being reset by the operator.
The instrument can also be programmed to display only one
unchanging color: GREEN,
AMBER, or RED.
This is a useful way to let an operator identify, at a glance,
process values in three separate locations, or to display
three different measurements such as Temperature, Pressure,
and Flow.
The innovative NEWPORT ®
iSeries
of meters/controllers features an extended Five (5) YEAR
warranty at no extra charge. The iSeries
packs a wealth of power and features into the smallest of
packages, utilizing COB (chip-on-board) and SMT (surface
mount technology) assembly techniques and automation. Every
iSeries
instrument is thoroughly calibrated and tested at several
stages throughout production. The iSeries
offers the highest accuracy for industrial instrumentation
at 0.03% of reading. The analog-to-digital conversion utilizes
proprietary 20-bit ASIC (application specific integrated
circuit) patented algorithms and smart filtering.
Universal
Inputs
The innovative iSeries
offers the broadest selection of signal inputs available
on one industrial instrument. The choices are easily
selected from the Menu with four front panel pushbuttons,
or by serial communications. |
|
 | |
The Universal Temperature & Process instrument (model "i") handles ten common types of thermocouples: K, J, T, E, R, S, B, C, N, and J DIN, multiple RTD's, and several Process (dc) Voltage ranges: 0-100 millivolt, 0-1 Volt, 0-10 Volt; Process Current range: 0-20 mA. This model also features built-in excitation, 24 Vdc @ 25 mA. with it's wide choice of signal inputs, this model is an excellent choice for measuring or controlling temperature with a thermocouple, RTD, or 4-20mA transmitter. |
The Strain & Process instrument (model " iS") measures inputs from Load Cells, Pressure Transducers, and most any strain gauge sensor as well as several Process (dc) Voltage ranges: 0 to 100 mVdc, -100 mVdc to 1Vdc and 0 to 10 Vdc; Process Current range: 0-20 mA. The "iS" has built-in excitation of 5 Vdc @ 40mA or 10 Vdc @ 60mA for bridge transducers. This "iS" model supports 4 and 6 wire bridge configurations, ratiometric and non-ratiometric measurements. The "iS" features fast and easy "in-process" calibration/scaling of the signal inputs to any engineering units. This model also features 10 Point Linearization which allows the user to linearize the signal input from extremely nonlinear transducers of all kinds.
The MIL Standard Nickel RTD with MIL-T-7990B curve is available as a Factory Setup.
Ordering Example: iS16D33-C24-FS (FS: preset for MIL-T-7990B curve, please specify range and accuracy).
Analog Output
The optional analog output can be programmed within a range of 0-10 Vdc or 0-20 mA. It is selectable as either a control output or as a calibrated retransmission of the process value-a unique feature among controllers.
Built-in Excitation Standard
Any excitation voltage between 5 and 24 Vdc is available by special order. Built-in excitation is not available with optional -C24 isolated RS-232/ RS-485 serial communications, -C4EI Ethernet option or -DC option.
Control Functions
The iSeries can control simple manual operation to ON-OFF and full Autotune PID control. (Selectable preset tune, adaptive tune, PID, PI, PD control modes.) The dual control outputs can be configured for a variety of independent control and alarm applications such as heat/heat, heat/cool, heat/alarm, cool/cool, cool/alarm or alarm/alarm. The ramp-to-setpoint feature allows the user to define the rate of rise to setpoint, minimizing thermal shock to the load during start-up. Maximum ramp time: 99.59 (HH.MM), Soak: 00.00 to 99.59 (HH.MM), Damping: 1 to 8 in unit steps.
For applications that do not require PID control, iSeries controllers are available in two special models that offer simplified programming. The iSeries “Limit Alarm” model (specify –AL option) is a conventional limit alarm. The iSeries “Simplified Menu” model (specify –SM option) offers simplified programming. The menu flowchart is similar to programmable digital panel meters that are used for on/off control or alarms. (Please see the iSeries operator’s manuals for programming details.)
Free Software
Free
software is provided for easy set-up, configuration and
data acquisition with the NEWPORT®
iSeries.
Free
ActiveX Controls
Free ActiveX Controls are provided for the iSeries,
making it easy to integrate the iSeries
with information systems using "ActiveX Containers" such
as Microsoft Visual Basic and Microsoft Excel as well as
with popular OLE and OPC compliant data acquisition, process
control, and industrial automation software from NEWPORT®,
GE Fanuc, Intellution, Rockwell Automation,
iconics, and Wonderware among others.
Optional Embedded Internet and Serial Communications
Featuring optional "Embedded Internet" (specify -EI option) the iSeries are the first instruments of their kind that connect directly to an Ethernet network and transmit data in standard TCP/IP packets, or even serve Web pages over a LAN or the Internet. The iSeries are also available with serial communications. With the "-C24" option, the user can select from the pushbutton menu between RS-232, RS-422, and RS-485, with straightforward ASCII commands or MODBUS.
Factory Setup and Configuration
Make installing your iSeries meter or controller easier by ordering it preconfigured by the factory. You specify the input types, scaling if applicable, set points, alarm points, etc. and we will program the instruments to your specific requirements in our calibration lab prior to shipment. For a checklist of factory setup parameters, please consult your NEWPORT® applications engineers.
Custom
Configurations
Custom color bezels and enclosures are available for Original
Equipment Manufacturers. Enhance the appearance of your
equipment design with custom colors. Consult the NEWPORT®
OEM Group.
|
1) Ethernet options are available for the i16D and iS16D Controller only.
2) -DC, -C24 or -C4EI not available with excitation.
3) Analog Output (Option 5) is not available with -AL units.
4) Strain iS16 is not available with -SM units.
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: *1 Ethernet options are available for the i16D and iS16D Controller only. *2 -DC, -C24 or -C4EI not available with excitation. *3 Analog Output (Option 5) is not available with -AL units *4 Analog Output (Option 5) and Ethernet Options are not available for the i16A controller. *5 For i16A** -AL: One Alarm and One Analog Retransmission *6 Strain iS16 is not available with -SM units
Ordering Example: (1) i1600 1/16 DIN Temp Meter with Single Display, No Output = $190
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
METER OPTIONS
|
| |
Select i16 for 1/16 DIN Temp Meter with Single Display i16D for 1/16 DIN Temp Meter with Dual Display iS16 for 1/16 DIN Strain Meter with Single Display iS16D for 1/16 DIN Strain Meter with Dual Display
|
(2)
|
Control Outputs
|
| |
Select 00 for No Output 22 for Two Solid State Relays 23 for One Solid State Relay and Form C SPDT 24 for 1 SSR and Pulse 10V dc 33 for 2 Relays - Form C SPDT 42 for Pulsed 10 V dc and SSR Relay 43 for Pulsed 10 V dc and Form C Relay 44 for 2 Pulsed 10 V dc 52 for Analog Output and SSR 53 for Analog output and Relay 54 for Analog output and pulse
|
(3)
|
Network Options
|
| |
Select Nothing(leave field blank) for no Network Option -C24 for Isolated RS-232 and RS-485, 300 to 19.2K baud -C4EI for Ethernet with Embedded Web Server + Isolated RS-485/422 -EI for Ethernet with Embedded Web Server
|
(4)
|
Power Supply
|
| |
Select Nothing(leave field blank) for Standard Power input 90-240Vac -DC for 12-36Vdc/24Vac
|
(5)
|
Menu Option
|
| |
Select Nothing(leave field blank) for no option -AL for for Limit Alarm Version (Alarm Menu, No PID Control) -SM for for Simplified Menu Version (ON/OFF Control, No PID Control)
|
(6)
|
Menu Option
|
| |
Select Nothing(leave field blank) for no option -FS for Factory Setup and Configuration
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | | |
|
 |
 |
|
|
|
|
Back to top |
|
|